ANTRACK V2

Note: Please note that the current price for this product does not include shipping fees. After ordering, kindly contact your sales manager/Customer Service Robot or email (sales@bitmain.com) to confirm your shipping method and obtain the final shipping cost.

Function BTC/BCH/BSV  SHA256  Hydro-cooling Miner
Specifications 1Set 24kW 4 Hydro-cooling Miner Rack I 80℃ Heating Capacity

Payment Method : USD | BTC | ETC | USDT(ERC20/BEP20)

Price

$8,888.00

Description

Product Glance Value
Model ANTRACK
Version V2
Capacity 4 units ANTMINER (Hydro) or
4 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro)
Maximum load,kW 24

 

Detailed Characteristics Value
Part 1: Mining Cabinet
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1200*600*1300
Size (Length*Width*Height), mm (with package) 1460*1330*780
Net weight, kg (without package) 130
Gross weight, kg (with package) 185
Network connection mode RJ45 Ethernet 10/100M
Power Supply
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump
Rated power, W 450
Noise, dBA@1m 60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Plate heat exchanger
Maximum heat exchange power, kW 30
Size (Length*Width* Height), mm 305*106*64
Diameter of water pipe connector, mm DN20
Part 2: External Cooler(1-3)
Hardware Configuration
Size (Length*Width*Height), mm (without package) 1340*570*1330
Size (Length*Width*Height), mm (with package) 1490*590*1495
Net weight, kg (without package) 235
Gross weight, kg (with package) 248
Power supply
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 21
Heat pump
Heating Capacity (typical), kW 32
Compressor Input (typical), kW 8
EER (typical) 3.0
Sound Level, Db(A) 50
Refrigerant R290
Heating water outlet temperature, °C 80
Fan
Rated power, W 500
Noise, dBA@1m 50
Size (Length*Height*Thickness), mm 551*551*160
Water pump
Rated power, W 180
Noise, dBA@1m 30
Size (Length*Width* Height), mm 130*551*129
Environment Requirements
Ambient temperature, °C -20~40
Water flow, L/min 32.0~40.0 (Cabinet side)
Water flow, L/min 32.0~40.0 (Heating side)
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 50
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(1-1) Caution: Wrong input voltage may probably cause miner damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.

 